Inside the Neonatal Intensive Care Unit (NICU), exposure to loud sounds such as acoustic medical alarms can have adverse effects on neonates, parents, and medical staff. With the aim of having an accurate overview of which and how often acoustic medical alarms occur, this paper presents a simple signal processing-based approach for detecting and recognizing automatically and permanently patient monitoring alarms inside the NICU. The proposed algorithm leverages from prior knowledge of the spectro-temporal structures of alarms to first detect each single occurrence of an alarm tone, and then group the detected tones into a known alarm pattern. A preliminary evaluation of the algorithm on a small set of 4-channel recordings capturing a simulated NICU soundscape shows that around 99% of the acoustic alarms are correctly recognized, and that around 99% of the recognized alarms are true alarms. The algorithm lends itself to efficient real-time implementation and to generalization to other alarm patterns as defined by the IEC 60601-1-8 standard.

An Algorithm for Automatic Acoustic Alarm Recognition in the Neonatal Intensive Care Unit

Spagnol, Simone;
2022-01-01

Abstract

Inside the Neonatal Intensive Care Unit (NICU), exposure to loud sounds such as acoustic medical alarms can have adverse effects on neonates, parents, and medical staff. With the aim of having an accurate overview of which and how often acoustic medical alarms occur, this paper presents a simple signal processing-based approach for detecting and recognizing automatically and permanently patient monitoring alarms inside the NICU. The proposed algorithm leverages from prior knowledge of the spectro-temporal structures of alarms to first detect each single occurrence of an alarm tone, and then group the detected tones into a known alarm pattern. A preliminary evaluation of the algorithm on a small set of 4-channel recordings capturing a simulated NICU soundscape shows that around 99% of the acoustic alarms are correctly recognized, and that around 99% of the recognized alarms are true alarms. The algorithm lends itself to efficient real-time implementation and to generalization to other alarm patterns as defined by the IEC 60601-1-8 standard.
2022
9781665481588
File in questo prodotto:
File Dimensione Formato  
ICFSP_2022.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: DRM non definito
Dimensione 3.37 MB
Formato Adobe PDF
3.37 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11578/322449
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact