Energy foundation piles can be an efficient cost-effective solution for ground source heat pump applications. As they are very different from standard ground heat exchangers, numerical or analytical models usually used to investigate their thermal performance must be carefully analysed before they can be applied. The total length of ground heat exchangers is a critically important factor in the overall design of a ground source heat pump. Ground thermal properties are the primary parameters affecting the size of ground heat exchangers. The thermal response test is the most commonly used procedure to determine the ground's thermal conductivity. The current study investigated a thermal response test on a 20 m long energy foundation pile equipped with a double U-tube circuit. The test measurements were interpreted using both the infinite line source model and inverse numerical analysis by means of a detailed model that was able to consider both the actual geometry of the pile and the axial heat transfer. The results indicated an approximately 50% difference between the two values of ground thermal conductivity. The effect of this evaluation on the calculation of the energy piles’ total length was first investigated utilizing a method outlined in the literature. The consequences on the long term energy performance of a ground source heat pump system were then investigated using numerical simulations and taking into consideration the effect of the spacing between the foundation piles. It was found that the total length calculated using the result based on the infinite line source model was about 20% lower than that obtained using the inverse numerical approach. An approximately 10% difference in the heat pump's seasonal energy efficiency was also found.
An appropriate use of the thermal response test for the design of energy foundation piles with U-tube circuits
EMMI, GIUSEPPE;
2017-01-01
Abstract
Energy foundation piles can be an efficient cost-effective solution for ground source heat pump applications. As they are very different from standard ground heat exchangers, numerical or analytical models usually used to investigate their thermal performance must be carefully analysed before they can be applied. The total length of ground heat exchangers is a critically important factor in the overall design of a ground source heat pump. Ground thermal properties are the primary parameters affecting the size of ground heat exchangers. The thermal response test is the most commonly used procedure to determine the ground's thermal conductivity. The current study investigated a thermal response test on a 20 m long energy foundation pile equipped with a double U-tube circuit. The test measurements were interpreted using both the infinite line source model and inverse numerical analysis by means of a detailed model that was able to consider both the actual geometry of the pile and the axial heat transfer. The results indicated an approximately 50% difference between the two values of ground thermal conductivity. The effect of this evaluation on the calculation of the energy piles’ total length was first investigated utilizing a method outlined in the literature. The consequences on the long term energy performance of a ground source heat pump system were then investigated using numerical simulations and taking into consideration the effect of the spacing between the foundation piles. It was found that the total length calculated using the result based on the infinite line source model was about 20% lower than that obtained using the inverse numerical approach. An approximately 10% difference in the heat pump's seasonal energy efficiency was also found.File | Dimensione | Formato | |
---|---|---|---|
2017_An appropriate use of the thermal response test for the design of energy foundation piles with U-tube circuits.pdf
non disponibili
Tipologia:
Versione Editoriale
Licenza:
Accesso ristretto
Dimensione
2.88 MB
Formato
Adobe PDF
|
2.88 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.