The design of a Ground Source Heat Pump (GSHP) system is critical because design choices affect the system’s energy performance and operating conditions. If the thermal load profile on the ground side is unbalanced the ground temperature will change throughout the time and, consequently, also the energy efficiency of the heat pump. This phenomenon is known as “ground thermal drift”. A possible solution to avoid this inconvenience is the adoption of a hybrid system. In this work a double source heat pump is investigated, i.e. the heat pump can use air or ground as heat source or heat sink. The case study is an office building located in the city of Padova (Italy). The building load profile is cooling dominant and a thermal drift can be observed in the monitoring records. A new water-to-water heat pump coupled to the boreholes and also to an air-cooled condenser was recently installed in order to tackle the thermal drift of the ground. Detailed computer simulations of the system were carried out via EnergyPlus software to investigate the energy performance of the system and the control strategy for switching between the heat sources (air or ground). The study shows the advantages of the double source heat pump.

A double source heat pump: a case study

Emmi G.
2018-01-01

Abstract

The design of a Ground Source Heat Pump (GSHP) system is critical because design choices affect the system’s energy performance and operating conditions. If the thermal load profile on the ground side is unbalanced the ground temperature will change throughout the time and, consequently, also the energy efficiency of the heat pump. This phenomenon is known as “ground thermal drift”. A possible solution to avoid this inconvenience is the adoption of a hybrid system. In this work a double source heat pump is investigated, i.e. the heat pump can use air or ground as heat source or heat sink. The case study is an office building located in the city of Padova (Italy). The building load profile is cooling dominant and a thermal drift can be observed in the monitoring records. A new water-to-water heat pump coupled to the boreholes and also to an air-cooled condenser was recently installed in order to tackle the thermal drift of the ground. Detailed computer simulations of the system were carried out via EnergyPlus software to investigate the energy performance of the system and the control strategy for switching between the heat sources (air or ground). The study shows the advantages of the double source heat pump.
File in questo prodotto:
File Dimensione Formato  
2018_A double source heat pump A case studyoksd_ighspa_2018_zarrella.pdf

non disponibili

Tipologia: Versione Editoriale
Licenza: Accesso ristretto
Dimensione 832.35 kB
Formato Adobe PDF
832.35 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11578/334097
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact