Masonry linings were the primary solution for tunnels before the introduction of reinforced concrete. As a result, many tunnels with masonry linings have been in operation for over a century and may exhibit damage due to ageing and prolonged water infiltration. Currently, there are no specific regulations for the static verification of masonry tunnels. These tunnels share characteristics and problems with historic masonry structures such as bridges and building facades. Therefore, the scientific literature and normative references developed for masonry heritage structures were here considered. This work focuses on estimating the masonry strength of tunnel linings. To demonstrate the proposed methodology and the addressed problems, the 'Giovi' tunnel on the historic Genoa-Valle del Po motorway in Genoa, Italy was selected as an exemplary case. The masonry's resistance is measured in situ using flat-jacks and estimated using methodologies proposed for both new and existing buildings. The comparison of these methodologies highlights the unique characteristics of tunnel linings, including thick mortar bed-joints and massive curved masonry walls, with only one free face.

Structural safety of existing masonry-tunnel-linings: A methodology derived from existing buildings approaches

Zanazzi, Elena
2024-01-01

Abstract

Masonry linings were the primary solution for tunnels before the introduction of reinforced concrete. As a result, many tunnels with masonry linings have been in operation for over a century and may exhibit damage due to ageing and prolonged water infiltration. Currently, there are no specific regulations for the static verification of masonry tunnels. These tunnels share characteristics and problems with historic masonry structures such as bridges and building facades. Therefore, the scientific literature and normative references developed for masonry heritage structures were here considered. This work focuses on estimating the masonry strength of tunnel linings. To demonstrate the proposed methodology and the addressed problems, the 'Giovi' tunnel on the historic Genoa-Valle del Po motorway in Genoa, Italy was selected as an exemplary case. The masonry's resistance is measured in situ using flat-jacks and estimated using methodologies proposed for both new and existing buildings. The comparison of these methodologies highlights the unique characteristics of tunnel linings, including thick mortar bed-joints and massive curved masonry walls, with only one free face.
File in questo prodotto:
File Dimensione Formato  
FABRE2024_Alessioetal.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
Structural safety.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: Creative commons
Dimensione 1.27 MB
Formato Adobe PDF
1.27 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11578/364385
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact